uLCm Dual Display 40A 63A 230V Din Rail Adjustable digital Over Under Voltage Relay Surge Protector Limit Over Current (1)
uLCm Dual Display 40A 63A 230V Din Rail Adjustable digital Over Under Voltage Relay Surge Protector Limit Over Current (2)
uLCm Dual Display 40A 63A 230V Din Rail Adjustable digital Over Under Voltage Relay Surge Protector Limit Over Current (3)
uLCm Dual Display 40A 63A 230V Din Rail Adjustable digital Over Under Voltage Relay Surge Protector Limit Over Current (4)
uLCm Dual Display 40A 63A 230V Din Rail Adjustable digital Over Under Voltage Relay Surge Protector Limit Over Current (5)
uLCm Dual Display 40A 63A 230V Din Rail Adjustable digital Over Under Voltage Relay Surge Protector Limit Over Current (6)
uLCm Dual Display 40A 63A 230V Din Rail Adjustable digital Over Under Voltage Relay Surge Protector Limit Over Current (7)
uLCm Dual Display 40A 63A 230V Din Rail Adjustable digital Over Under Voltage Relay Surge Protector Limit Over Current (8)
uLCm Dual Display 40A 63A 230V Din Rail Adjustable digital Over Under Voltage Relay Surge Protector Limit Over Current (9)

ขาย uLCm Dual Display 40A 63A 230V Din Rail Adjustable digital Over Under Voltage Relay Surge Protector Limit Over Current ราคาที่ดีที่สุด

0
การให้คะแนน
฿638 - ฿663
เรือจาก
จังหวัดพะเยา
Color
40A
63A

รายละเอียดสินค้า

Functions: 1.Over-voltage protection 2.Under-voltage protection 3.Over-current protection 4.Automatic recovery 5.Voltage display(voltage measurement) 6.Current display (current measurement) Product Parameters: 1.Model number:TVPS1-63B 2.Power supply:230VAC 50/60Hz 3.Max.Loading power:1~40A Adjustable(default:40A) 1~63A Adjustable(default:63A) 4.Over-voltage protection value range:230V~300~OFF(default:270V) Over-voltage recovery voltage range:225V--295V(default:250V) Over-voltage protection action time:0.1s~30s(default value:0.5s) Over-voltage r ecovery delay time:1s~500s(default:30s) 5.Under-voltage protection value range:140V--210V --OFF(default:170V) Under-voltage recovery voltage range:145V--215V (default:190V) Under-voltage protection action time:0.1s~30s(default:0.5s) Under-voltage r ecovery delay time:1s~500s(default:30s) 6.Over-current adjustment range:1-40A (default:20A) 1-63A (default:40A) Over-current action range:0.1~30 second (default:0.5s) Over-current r ecovery delay time:1s~500s(default:30s) 7.Power-on delay time:1s~500s(default:10s) 9.Power consumption : 2W 10.Electric machinery life : 100,000 times 11.Installation:35mm DIN rail Noted: When you first connect the product, you have to wait about 10 second( Power-on delay time:1 s~50 0s(default:10 s)), after the red light turn off, then the product will work.

ข้อมูลจำเพาะของผลิตภัณฑ์

หมายเลขมอก.nothing

จากร้านเดียวกัน

รายการที่เกี่ยวข้อง

คุณอาจชอบ