Mini RCBO Residual Current Circuit Breaker with Overcurrent Protection ELCB For Low Voltage 10A 16A 20A 25A 32A 63A With (1)
Mini RCBO Residual Current Circuit Breaker with Overcurrent Protection ELCB For Low Voltage 10A 16A 20A 25A 32A 63A With (2)
Mini RCBO Residual Current Circuit Breaker with Overcurrent Protection ELCB For Low Voltage 10A 16A 20A 25A 32A 63A With (3)
Mini RCBO Residual Current Circuit Breaker with Overcurrent Protection ELCB For Low Voltage 10A 16A 20A 25A 32A 63A With (4)
Mini RCBO Residual Current Circuit Breaker with Overcurrent Protection ELCB For Low Voltage 10A 16A 20A 25A 32A 63A With (5)
Mini RCBO Residual Current Circuit Breaker with Overcurrent Protection ELCB For Low Voltage 10A 16A 20A 25A 32A 63A With (6)
Mini RCBO Residual Current Circuit Breaker with Overcurrent Protection ELCB For Low Voltage 10A 16A 20A 25A 32A 63A With (7)
Mini RCBO Residual Current Circuit Breaker with Overcurrent Protection ELCB For Low Voltage 10A 16A 20A 25A 32A 63A With (8)
Mini RCBO Residual Current Circuit Breaker with Overcurrent Protection ELCB For Low Voltage 10A 16A 20A 25A 32A 63A With (9)

ขาย Mini RCBO Residual Current Circuit Breaker with Overcurrent Protection ELCB For Low Voltage 10A 16A 20A 25A 32A 63A With ราคาที่ดีที่สุด

0
การให้คะแนน
฿853 - ฿1,311
เรือจาก
จังหวัดกรุงเทพมหานคร
สี
3P
4P
2P
ขนาด
6A
50A
25A
20A
40A
16A
63A
10A
32A

รายละเอียดสินค้า

TXD7-63 series new leakage circuit breakers (earth leakage circuit breaker) is designed based on the leakage tripping device accessories and TXB7N-63 circuit breaker with a reduced design, 2P / 3P / 4P leakage are narrower than ordinary DZ47LE circuit breaker, at the same time it maintain the same current characteristics as the TXB7N, its mechanical assembly can be completed by the enterprise in the factory, or in the field. Leakage trip characteristic parameters set by the factory, the user can not adjust, can not open the leakage release to avoid affecting performance. Frame rated current of leakage release is 63A, can be connected to the wire of 25mm². The earth leakage circuit breaker has an indication device which is used for indicating the leakage action. The leakage circuit breaker can be closed only after the indication device has been reset. And it has the test device with a self-reset button, press the button, the internal circuit generates an analog residual current to make circuit breaker break. The test device shall be tested periodically, once a month. ◆ Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. ◆ Altitude: The altitude of installation site does not exceed 2000m. ◆ Atmospheric conditions: The location of the air relative humidity in the highest temperature + 40℃ for not more than 50%; In the low temperature can have higher relative humidity. For example, + 20℃ for 90% . ◆ Installation categories: Ⅱ, Ⅲ level. ◆ pollution level: 2. ◆ Installation: mounted on the TH35-7 steel rail. ◆ Installation conditions: The external magnetic field in the vicinity of the circuit breaker installation site does not exceed 5 times of the geomagnetic field in any direction; Residual current operated circuit breakers should be installed vertically; Handle-up means power-on; Installation site without significant impact and vibration. ◆ Wiring method: tighten the wiring with screws.

ข้อมูลจำเพาะของผลิตภัณฑ์

หมายเลขมอก.nothing

จากร้านเดียวกัน

รายการที่เกี่ยวข้อง

คุณอาจชอบ