ขาย เครื่องมือปรับแรงดันไฟฟ้าอัจฉริยะแรงดันไฟฟ้าใต้วงจร ราคาที่ดีที่สุด
0
การให้คะแนน
฿469
53% OFF
฿223 - ฿260
เรือจาก | ต่างประเทศ |
---|---|
Type | 63A 40A |
รายละเอียดสินค้า
Features:
1.Overvoltage protection, undervoltage protection and voltage display (voltage measurement).
2.Overvoltage protection and overvoltage recovery value are both adjustable, overvoltage protection action time is adjustable.
3.Undervoltage protection value and undervoltage recovery value are both adjustable, undervoltage protection action time is adjustable.
4.Fault recovery delay time and power-on delay time-on time are adjustable.
5.Reset mode selection, fault inquiry and factory reset function.
Specification:
Type:40A/63A(Optional)
Rated voltage:230VAC 50/60Hz
Rated current:40A, 63A
Overvoltage protection value range:221V-300V-OFF adjustable (default 280V)
Overvoltage recovery voltage mediation range:220V-299V (default 250V)
Overvoltage protection action time:0.1 seconds - 10 seconds (default 0.1 seconds)
Undervoltage protection value rang:219V-150V-OFF adjustable (default 160V)
Undervoltage recovery voltage mediation range:151V-220V (default 180V)
Undervoltage protection action time:0.1 seconds - 10 seconds (default 0.1 seconds)
Failure recovery delay time:2 seconds - 512 seconds (default 60 seconds)
Power-on delay time:2 seconds - 255 seconds (default 2 seconds)
Power consumption:≤2W
Electrical mechanical life:≥4000 times
Dimensions:81 x 36 x 60mm / 3.19 x 1.42 x 2.36in
Installation method:DIN rail
Working environment:Temperature -25℃~+40℃ Humidity
Setting method:
Press and hold ''SET'' for 3 seconds, please set the parameter value to be modified as follows, 'Up Triangular Shape' or 'Down Triangular Shape' key to adjust the set value. Only ''END'' appears, press ''SET'' again, the setting data will be saved and effective.
Setup steps:
1.
Setting content:Overvoltage protection value
Digital tube display:280
Indicator status:Overvoltage indicator flashes
Setting instructions:Setting range 221V-300V-OFF (default 280V)
2.
Overvoltage recovery value
250
Overvoltage indicator flashes
Setting range 220V-299V (default 250V)
3.
Overvoltage protection action time
0.1
Overvoltage indicator flashes
Setting range 0.1 second - 10 seconds (default 0.1 second)
4.
Undervoltage protection value
160
Under voltage indicator flashes
Setting range 219V-150V-OFF adjustable (default 160V)
5.
Undervoltage recovery value
180
Under voltage indicator flashes
Setting range 151V-220V (default 180V)
6.
Undervoltage protection action time
0.2
Under voltage indicator flashes
Setting range 0.1 second - 10 seconds (default 0.1 second)
7.
Failure recovery delay time
60
Overvoltage indicator and undervoltage indicator flash simultaneously
Setting range 2 seconds - 512 seconds (default 60 seconds)
8.
Power-on delay time
2
Overvoltage indicator and undervoltage indicator flash simultaneously
Setting range 2 seconds - 255 seconds (default 2 seconds)
9.
Reset mode
AU
Overvoltage indicator and undervoltage indicator flash simultaneously
''AU'' means the default fault reset mode is auto reset. Press 'Up Triangular Shape' key to set the fault reset mode to ''HA''. HA indicates manual reset. When the manual reset mode HA is set, the protector will not automatically supply power after power-on. The "SET" will close the power supply. When the line voltage fails, the protector will not restore the power even after the line fault is removed. You must manually press the "Settings" button on the protector to restore the protector.
10.
Fault inquiry
1UL Overvoltage indicator and undervoltage indicator flash simultaneously The digital tube displays ''1UL'', and the overvoltage indicator and undervoltage indicator flash simultaneously.For example: ''1UL'' means that the last fault is an undervoltage fault, UL means undervoltage, UH means overvoltage, press 'Up Triangular Shape' key to query the last 5 faults, if there is no fault, only ''1'' number is displayed without ''UL'' or "UH".
11.
End
END
Overvoltage indicator and undervoltage indicator flash simultaneously
This setup is complete.Press the setting button again, the protector saves the data, exits the setting state and enters the running state, and the digital tube displays the current voltage value.
Package List:
1 x Protector
Note:M. Voltage indicator status indication: When the voltage is over voltage, the voltage indicator flashes quickly. When the voltage is under voltage, the undervoltage indicator flashes slowly. When the voltage is low, the overvoltage indicator is always on.
N. Warranty period mark: During the one-year warranty period of the protector's accumulated power supply, the over-voltage indicator and under-voltage indicator are always on, and the protector is fully energized for one year after the warranty period, over-voltage indicator and under-voltage When the indicator light is in the normal state, it will not light. Only when there is overvoltage or undervoltage, the indicator will flash, ind