Compatible ECG Cable 10 Leads Banana IEC/AHA for MAC 400, MAC 1000 MPyG (1)
Compatible ECG Cable 10 Leads Banana IEC/AHA for MAC 400, MAC 1000 MPyG (2)
Compatible ECG Cable 10 Leads Banana IEC/AHA for MAC 400, MAC 1000 MPyG (3)
Compatible ECG Cable 10 Leads Banana IEC/AHA for MAC 400, MAC 1000 MPyG (4)

ขาย Compatible ECG Cable 10 Leads Banana IEC/AHA for MAC 400, MAC 1000 MPyG ราคาที่ดีที่สุด

0
การให้คะแนน
฿2,864 - ฿3,051
เรือจาก
จังหวัดกรุงเทพมหานคร
สี
AHA snap
IEC snap
AHA Grabber
IEC Grabber
AHA banana
IEC banana

รายละเอียดสินค้า

Compatible: MAC 1000, MAC 1100, MAC 1200, MAC 1600, MAC 2000, MAC 3500, MAC 400, MAC 500, MAC 600, MAC 800, Microsmart M EC005A One-piece EKG CABLE and leadwires , AHA, Banana EC005AI One-piece EKG CABLE and leadwires , IEC, Banana EC005B One-piece EKG CABLE and leadwires , AHA , Grabber EC005BI One-piece EKG CABLE and leadwires , IEC, Grabber EC005C One-piece EKG CABLE and leadwires ,AHA, Snap EC005CI One-piece EKG CABLE and leadwires , IEC, Snap Technical Specifications: Category EKG Certifications FDA, CE, ISO Connector DB-15 Connector Connector Banana Latex-free Yes Lead Cable Color Gray Lead Cable Diameter 2.60 mm Lead Cable Length Limb 1.2M Lead Cable Length V 0.8M Lead Cable Material TPU Jacket Lead Color Coding AHA/IEC Lead Number 10 Packaging Type Bag Packaging Unit 1 Patient Size Adult/Pediatric Resistance 10K Ohms Sterile No Total Cable Length 3.2M Trunk Cable Color Gray Trunk Cable Diameter 6 mm Trunk Cable Length 2M Trunk Cable Material TPU Warranty 12 months Performance and selling point Environment requirements Environment temperature :0°C~40°C Relative humidity:15%~85% Atmospheric pressure:86kpa~106kpa Package and storage Every ECG cable should be packaged singly,It should be stored in drafty indoor without corrosive gas. The storage conditions are below:(1)Environment temperature:-10°C~+40°C(2)Relative humidity:≤80% Comply with EC、ISO13485 How to use Connect the ECG/EKG lead wrie with the adaptive patient monitor ,and check whether the opertion is the same as the operation instructions of operation manual. The ECG/EKG electrode of lead wire should be connected on the patient in order,the lead wire should be connected separately to avoid entwine,otherwise it may cause interference during the monitoring,such as heart rate fluctuation,waveform fluctuation etc.

ข้อมูลจำเพาะของผลิตภัณฑ์

ระยะเวลาการรับประกัน6 เดือน
ประเภทการประกันประกันจากผู้ผลิต
จำนวนช่องหน่วยความจำ1
หมายเลขมอก.nothing

จากร้านเดียวกัน

รายการที่เกี่ยวข้อง

คุณอาจชอบ